Mapei Bonding AgentNo. 08 / 53
Epojet LV Technical Data Sheet (TDS)
Bonding Agent to EN 1504-5 concrete injection.
Epojet LV is the low viscosity grade of the Mapei two component epoxy injection resin, mixed 3.2 parts A to 0.8 part B into a liquid of 140 mPa.s that runs into microcracks a paste cannot reach, on dry or wet concrete. That is what separates it from Eporip, the fluid paste poured into cracks that have been opened out at 1.35 kg per litre, and from Adesilex PG1 and PG2, which seal the crack face and hold the packers while Epojet LV is pumped in behind them.
- Sealing static cracks in concrete by low pressure injection
- Bonding steel plates to concrete by low pressure injection
- Structural repair of cracked beams, pillars and floors
- Repair of crumbling architectural concrete, wall coverings and architectural elements
- Sealing cracks in cementitious screeds
- Restoring concrete structures damaged by earthquakes, settlements or impacts
Build a list across products and send it once, or ask about Epojet LV on WhatsApp now.
- Class
- EN 1504-5 concrete injection
- Consumption
- 1.1 kg/m² per mm
- Pack we stock
- 4 kg
- Colour
- transparent yellow, both components and the mix
Mapei document 00365 · revision 11-2024
About Epojet LV
It meets EN 1504-5 for concrete injection and fills a 0.1 mm crack in 1 minute 30 seconds in dry and in damp sand. Consumption is 1.1 kg per litre of cavity. What decides the job is temperature: never below +10°C, and workability drops from 35 minutes at +23°C to 15 minutes at +30°C.
Documentation
Related documentation
Technical data sheet
Revision 11-2024 · 2.8 MB · PDF
Epojet LV as the manufacturer publishes it, unaltered.
DownloadSafety data sheet
Revision 2-2026 · 0.2 MB · PDF
For the method statement and the site file.
DownloadSubmittal pack
Data sheet, safety data sheet and our authorisation letter together, for a consultant submittal.
Request
Coverage calculator
How much you need.
The sheet states 1 to 10 mm.
As published in the data sheet
110kg
- 1.1 kg/m2 per mm
- 2 mm thick
- over 50 m2
Order 28 packs of 4 kg kit, component A 3.2 kg plus component B 0.8 kg
Taken from the Epojet LV data sheet: CONSUMPTION: Epojet LV Bonding concrete-steel: 1.1 kg/m2 per mm of thickness. Emirates edition, document 365-11-2024 (UAE). No site allowance is added unless you turn one on. The sheet prints neither a maximum nor a minimum thickness for the bonded plate rate, so the bounds on this control are ours, not the manufacturer's. The rate agrees with the other two figures the same sheet prints: sealing cracks by injection takes 1.1 kg per litre of cavity, and the density of the mixed resin is 1.1 kg per litre, since one square metre at one millimetre is one litre. The components are pre dosed 3.2 to 0.8, so a part kit has to be weighed on a precision scale, and the mix has to be injected inside a workability time of 35 minutes at +23°C or 15 minutes at +30°C.
Application
Where it is used.
- 01Sealing static cracks in concrete by low pressure injection
- 02Bonding steel plates to concrete by low pressure injection
- 03Structural repair of cracked beams, pillars and floors
- 04Repair of crumbling architectural concrete, wall coverings and architectural elements
- 05Sealing cracks in cementitious screeds
- 06Restoring concrete structures damaged by earthquakes, settlements or impacts
Specification
Technical data.
- EN 1504-5 concrete injection
| Classification | EN 1504-5 concrete injection |
|---|---|
| Coverage | Sealing cracks: 1.1 kg per litre of cavity to be filled. Bonding concrete to steel: 1.1 kg/m² per mm of thickness. |
| Pack size | 4 kg kit (component A 3.2 kg, component B 0.8 kg) |
| Pot life | 35 minutes at +23°C, 15 minutes at +30°C (EN ISO 9514) |
| Colours | transparent yellow, both components and the mix |
| Mixing ratio | component A : component B = 3.2 : 0.8 |
| Application temperature | from +10°C to +35°C |
| Consistency | very fluid liquid |
| Storage and shelf life | 24 months in their original packaging stored at a temperature between +5°C and +30°C |
| Density | 1.1 kg/l for the mix (component A 1.1, component B 0.98) |
| Viscosity | 140 mPa.s Brookfield for the mix (shaft 1 - 50 revs) |
| Setting time | 7 to 8 hours at +23°C, 2 to 3 hours at +30°C |
| Complete hardening time | 7 days |
| Compressive strength | 70 N/mm² (ASTM D 695) |
| Tensile strength | 50 N/mm² dry, 40 N/mm² damp (EN ISO 527) |
| Modulus of elasticity | 2900 N/mm² dry, 2600 N/mm² damp (EN ISO 527) |
| Glass transition temperature | above +40°C (EN 12614) |
| Injection class | a 0.1 mm crack filled in 1 minute 30 seconds in both dry and damp sand, against a requirement of under 4 minutes (EN 1771) |
| Cleaning agent | a solvent such as ethyl alcohol or toluene, before the product dries |
Typical values as Mapei prints them in the data sheet for Epojet LV. Manufacturers revise their sheets, so ask us for the current edition before you specify.
On site
Packs, mixing and storage.
We stock
4 kg kit (component A 3.2 kg, component B 0.8 kg). Other pack sizes can usually be brought in on a project order, so tell us the quantity before you assume what is available.
Mixing
component A : component B = 3.2 : 0.8. Mix mechanically to a uniform lump free consistency, and follow any standing time the data sheet gives before remixing. Do not add extra water to recover workability, which lowers strength.
Working time
35 minutes at +23°C, 15 minutes at +30°C (EN ISO 9514). Mix only what can be placed inside it. UAE summer temperatures shorten every working time printed on a sheet.
Storage
24 months in their original packaging stored at a temperature between +5°C and +30°C in unopened packaging, stored dry and out of direct sun. Heat and humidity both shorten it.
Cleaning
a solvent such as ethyl alcohol or toluene, before the product dries. Clean tools before the material hardens; once cured it comes off by mechanical means only.
For quantity surveyors
BOQ clause.
Supply and apply Epojet LV, a bonding agent manufactured by Mapei, classified EN 1504-5 concrete injection. Allow 1.1 kg/m2 per mm, as published by the manufacturer. Mix at component A : component B = 3.2 : 0.8. Supplied in 4 kg kit (component a 3.2 kg, component b 0.8 kg). Prepare the substrate and apply strictly in accordance with the manufacturer's current technical data sheet. Rates are for estimating and exclude wastage.
| Product | Epojet LV |
|---|---|
| Manufacturer | Mapei |
| Type | Bonding Agent |
| Classification | EN 1504-5 concrete injection |
| Consumption | 1.1 kg/m2 per mm |
| Pack size | 4 kg kit (component A 3.2 kg, component B 0.8 kg) |
| Mixing ratio | component A : component B = 3.2 : 0.8 |
| Pot life | 35 minutes at +23°C, 15 minutes at +30°C (EN ISO 9514) |
| Unit of measurement | m2 |
Frequently Asked Questions
Epojet LV is classified EN 1504-5 concrete injection according to the manufacturer's technical data sheet, as stated in the manufacturer's technical data sheet.
As per the TDS: Sealing cracks: 1.1 kg per litre of cavity to be filled. Bonding concrete to steel: 1.1 kg/m² per mm of thickness.
4 kg kit (component A 3.2 kg, component B 0.8 kg)
You can download the official Epojet LV technical data sheet as a PDF directly from this page, revision 11-2024, sourced from the manufacturer. For prices and stock in the UAE, contact Lapiz Blue on WhatsApp.
Related Products

Adesilex PG2
View TDS and specifications

Adesilex PG2 TG
View TDS and specifications

Adesilex PG4
CE EN 1504-4
View TDS and specifications

Dynamon MR 2100
ASTM C494, EN 934-2
View TDS and specifications

Dynamon MR 3000
ASTM C494, EN 934-2
View TDS and specifications

Dynamon SR 1200
ASTM C494, EN 934-2
View TDS and specifications
All Concrete Additives and Repair SystemsEvery Mapei product and the distributor page
On the van
Tools for this job.
Epojet LV in the UAE
Tell us the area. We will quote the job.
Lapiz Blue supplies Mapei from Dubai, Abu Dhabi and Sharjah. Send the quantity of Epojet LV you need, or describe the job and we will work it out with you.